An LG dryer code usually tells you one of three things: the vent is choked, the power supply is off, or a sensor stopped reporting. These are the codes we see on LG electric, gas, steam, condensing and heat pump dryers, with notes where a heat pump model reads the same code differently. Start with the safe checks, and if the code stays, an authorized LG service provider can measure the circuit and replace only what failed.










| Code | Name | What the dryer detected |
|---|---|---|
d80 / d85 / d90 / d95 | Vent blocked (Flow Sense) | The dryer's Flow Sense check measured weak exhaust airflow. The number is roughly how restricted the vent is in percent, so d95 is worse than d80. |
tE1 | Temperature sensor fault | On electric and gas dryers the exhaust thermistor on the blower housing reads open or shorted. On heat pump dryers tE1 points to the drum outlet sensor. |
tE2 | Sensor out of range or very cold | On electric and gas dryers tE2 means the thermistor reads shorted, open or far too cold, which can happen when cold outdoor air pours back in through the vent. On heat pump dryers tE2 points to the compressor discharge sensor. |
tE3 | Heater not heating or overheated | On condensing dryers tE3 means the heater stopped working, often because a safety cut off tripped from overheating or the dryer is not getting full 240 volts. On heat pump dryers it points to the heater sensor. |
tE4 | Steam or evaporator sensor fault | On steam dryers tE4 means the steam generator temperature sensor reads out of range. On heat pump dryers it points to the evaporator inlet sensor. |
tE5 | Heat pump sensor fault | On heat pump dryers tE5 points to a refrigeration temperature sensor, the evaporator outlet sensor on most models and the compressor inlet sensor on others. |
tE6 | Heat pump or steam sensor fault | Depending on the model, tE6 points to the compressor outlet sensor or to the steam generator sensor. |
tE7 | Evaporator inlet sensor fault | On some heat pump dryers tE7 means the evaporator inlet temperature sensor reads open or shorted. |
dE | Door not detected as closed | The door switch is not telling the board the door is shut, so the dryer will not start. |
dE2 | Door lock not engaging | Some condensing and WashTower dryers lock the door like a front load washer. The board never got the signal that the lock closed. |
nP | No proper power | The dryer is not getting the voltage it needs. On a 240 volt electric dryer the classic cause is one of the two breaker legs being off, so the drum may turn but nothing heats. |
PS | Power supply problem | Supply voltage is too low, too high or not matching what the dryer is rated for. |
PF | Power was interrupted | Power to the dryer dropped out during a cycle. |
HS | Moisture sensor reading | On older dryers HS is a humidity sensor fault. It often shows when the installation check or Flow Sense test runs while the dryer is still warm. On newer dryers it appears only in install mode when the moisture sensor bars are shorted. |
AE | Compressor fault (heat pump) | On heat pump dryers AE means the compressor failed to run properly. |
LE1 | Drum motor locked | The motor could not turn the drum. On belt models the same motor also spins the blower, so a dryer sheet in the blower can stop it. |
LE2 | Drum motor or compressor fault | On condensing dryers LE2 means the drum motor draws too little current, often from a clogged lint filter or no drive from the board. On heat pump dryers LE2 is a compressor fault. |
LE3 | Dry fan restricted (heat pump) | On heat pump dryers with a separate drying fan, the fan tried three times to start and failed. |
FO / IF | Lint filter missing | The dryer does not sense the lint filter, so it will not start. A magnet in the filter closes a switch in the housing. Some models show FO, others IF. |
F1 | Drum too hot | Temperature inside the drum got too high, almost always because air is not flowing. |
OE / drN | Condensed water not draining | On condensing and heat pump dryers that drain to a standpipe, the water level did not drop after the pump ran. |
E13 | Drain pump fault | On some condensing dryers this means the drain pump failed or the drain line is blocked. |
CC | Condenser cover open (heat pump) | The dryer does not sense the lower condenser cover as closed. |
bF1 | Box fan fault (heat pump) | The small box fan in the tub cover is not running correctly. |
IrE | IR sensor fault (test mode) | Shown only in the test program. The board cannot detect the infrared sensor in the drum lamp. |
gAS | Gas dryer not heating | The gas dryer did not see the temperature rise it expected. On the display it can look like 9A5. |
E1 | Steam generator overheating | On steam dryers the steam generator water got far too hot, over about 320 F. |
E3 | No water for steam | On steam dryers the steam generator did not get water, so it could not make steam. |
E4 | Steam not heating up | The steam generator did not reach about 221 F within 80 seconds. |
E5 | Steam pump fault (test mode) | Seen only in the test program on steam dryers. The steam pump is not performing. |
Add | Steam water tank empty (info) | The steam water drawer is empty or not fully closed. It is a reminder, not a fault. |
big | Large load setting (info) | Shown on Steam Fresh when the large load size is selected. Not a fault. |
EE | Control memory fault | The memory chip on the main board failed its self check. |
nC / nU | NFC module fault (test mode) | Only in the test program. The NFC tag used for phone pairing is open or shorted. |
nE | Wi-Fi module trouble (test mode) | Only in the test program. The Wi-Fi module and your router are not communicating properly. |
nF | Not connected to Wi-Fi (info only) | Not a fault. The dryer has not been linked to your home network. It shows only in the test program. |
Tell us the code and model, we usually know the fix before we arrive. Same-day across Orange County.