The motor could not turn the drum. On belt models the same motor also spins the blower, so a dryer sheet in the blower can stop it.


We check the motor windings (about 20 ohms per pair on condensing models, 10 to 20 on heat pump models) and the 220 to 240 volt drive from the board. On direct drive models we inspect the rotor, stator bolts and gear assembly, and pull foreign objects out of the blower.
The motor could not turn the drum. On belt models the same motor also spins the blower, so a dryer sheet in the blower can stop it.
Unplug the dryer and turn the drum by hand. It should move freely. Remove any clothing stuck between the drum and the door. Do not overload the dryer.
We check the motor windings (about 20 ohms per pair on condensing models, 10 to 20 on heat pump models) and the 220 to 240 volt drive from the board. On direct drive models we inspect the rotor, stator bolts and gear assembly, and pull foreign objects out of the blower.
Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.