LG APPLIANCE REPAIR Factory Authorized Service · Irvine, CA

LG Dryer d80 / d85 / d90 / d95 Code: Vent blocked (Flow Sense)

The dryer's Flow Sense check measured weak exhaust airflow. The number is roughly how restricted the vent is in percent, so d95 is worse than d80.

Call (949) 876-7373 Text Us
✅ Factory Authorized LG Service Provider 🛡️ Licensed & Insured ⚡ Same-Day Appointments 🔧 90-Day Parts & Labor Warranty
LG dryer

Try these quick checks first (free & safe)

  1. Clean the lint screen and look in the screen slot for lint buildup.
  2. Go outside with the dryer running and feel for strong air at the vent hood.
  3. Clear lint, nests or a stuck flap at the outside hood.
  4. Replace white vinyl or thin foil flex hose behind the dryer with 4 inch rigid or semi rigid metal duct, kept short and straight.

What our technician checks

We measure exhaust back pressure, which should be about 0.6 inches of water column or less, and work out the real duct length, counting each bend as about 10 feet. Long runs, roof vents with screens and crushed flex hose are the usual causes. A vent full of lint is a fire risk, so we do not recommend running the dryer with d90 or d95 until the duct is cleaned or rerouted.

LG dryer repair in Irvine and Orange County →

LG d80 / d85 / d90 / d95 code: FAQ

What does the d80 / d85 / d90 / d95 code mean on an LG dryer?+

The dryer's Flow Sense check measured weak exhaust airflow. The number is roughly how restricted the vent is in percent, so d95 is worse than d80.

Can I clear the d80 / d85 / d90 / d95 code myself?+

Clean the lint screen and look in the screen slot for lint buildup. Go outside with the dryer running and feel for strong air at the vent hood. Clear lint, nests or a stuck flap at the outside hood. Replace white vinyl or thin foil flex hose behind the dryer with 4 inch rigid or semi rigid metal duct, kept short and straight.

What does a technician check for d80 / d85 / d90 / d95?+

We measure exhaust back pressure, which should be about 0.6 inches of water column or less, and work out the real duct length, counting each bend as about 10 feet. Long runs, roof vents with screens and crushed flex hose are the usual causes. A vent full of lint is a fire risk, so we do not recommend running the dryer with d90 or d95 until the duct is cleaned or rerouted.

Other common LG Dryer Error Codes

tE1: Temperature sensor fault tE2: Sensor out of range or very cold dE: Door not detected as closed nP: No proper power PS: Power supply problem HS: Moisture sensor reading AE: Compressor fault (heat pump) LE1: Drum motor locked LE2: Drum motor or compressor fault

LG Dryer Showing d80 / d85 / d90 / d95?

Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.

Call (949) 876-7373 Text Us
⚡ $25 OFF For new & referred customers