The board did not see water flow when it opened the water valve. It can be a failed flow meter or simply no water reaching the fridge.


We confirm water pressure at the inlet, then disconnect the flow meter and check its resistance (roughly 4 to 30 kilohms depending on the style). We also measure the water valve coils: about 360 to 420 ohms on 120 volt AC valves, and on DC valves we look for at least 20.4 volts DC from the board.
The board did not see water flow when it opened the water valve. It can be a failed flow meter or simply no water reaching the fridge.
Make sure the water supply valve to the fridge is fully open. Check the line behind the fridge for kinks. Replace the water filter if it is past due. A clogged filter starves the flow.
We confirm water pressure at the inlet, then disconnect the flow meter and check its resistance (roughly 4 to 30 kilohms depending on the style). We also measure the water valve coils: about 360 to 420 ohms on 120 volt AC valves, and on DC valves we look for at least 20.4 volts DC from the board.
Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.