LG APPLIANCE REPAIR Factory Authorized Service · Irvine, CA

LG Refrigerator Error Codes: What Each Code Means

Most LG refrigerators show an error as Er on one side of the display and a short code on the other, like Er IF or Er FF. Some of these are simple fixes you can try in a few minutes, others mean a fan, sensor or board needs a technician. Here is what each code means and what we check as a factory authorized LG repair team.

Call (949) 876-7373 Text Us
CodeNameWhat the refrigerator detected
Er IFIce compartment fan not respondingThe main board stopped getting a speed signal back from the small fan that pushes freezer air into the ice compartment. Most of the time the fan blade is frozen in place by ice.
Er FFFreezer fan not respondingThe main board lost the feedback signal from the freezer evaporator fan. Ice built up around the blade is the usual reason, which often means the defrost system is the real problem.
Er CFCondenser fan not respondingThe fan in the machine compartment at the back bottom of the fridge stopped reporting that it is spinning. That fan cools the compressor and condenser.
Er dHDefrost heater circuit faultThe defrost sensor did not warm up to about 40 degrees within 80 minutes of a defrost cycle starting, or the heater circuit is open or shorted. Some models show rdH for the fridge section or fdH for the freezer.
Er dSDefrost sensor faultThe main board is not getting a usable reading from the defrost sensor clipped to the evaporator.
Er rSFridge temperature sensor faultThe main board reads the fresh food sensor as open or shorted. The control only sets this code when it sees 0 or 5 volts DC on that line.
Er rS2Second fridge sensor faultSome models use a second fresh food sensor. The board sees that one as open or shorted.
Er FSFreezer temperature sensor faultThe main board reads the freezer sensor as open or shorted, which leaves the control guessing at freezer temperature.
Er rFFridge section fan not respondingThe main board lost the feedback signal from the fan that moves air into the fresh food section.
Er COMain board and display not talkingThe main board and the display board in the door stopped communicating with each other.
Er CO2Display and dispenser board not talkingThe display board and the dispenser board stopped communicating.
Er C1Display and dispenser power board not talkingEither the display board or the dispenser power board stopped sending or receiving data.
Er SdDispenser sub board not talkingThe dispenser sub board lost communication. Depending on the model it talks either to the main board or to the display board.
Er SCDoor color lighting board not talkingOn InstaView models with adjustable color lighting, the small lighting board under the hinge cover lost contact with the display board.
Er gFWater flow meter errorThe board did not see water flow when it opened the water valve. It can be a failed flow meter or simply no water reaching the fridge.
Er SSPantry drawer sensor faultThe main board is not getting a usable signal from the sensor in the temperature controlled pantry drawer.
Er CSConvertible drawer sensor faultThe sensor in the convertible drawer, which gets cold air from the freezer, reads as shorted or disconnected.
Er HSHumidity sensor faultThe humidity sensor reads as shorted or disconnected. Some displays show it as H5 or H05.
Er rtRoom temperature sensor faultThe sensor that reads kitchen air temperature is shorted or disconnected. The fridge uses that reading to adjust cooling.
Er ISIn door ice maker sensor faultThe main board lost the signal from the icing sensor on the in door ice maker. Some freezer only ice maker models use this same code for their single ice maker sensor.
Er IHFreezer ice maker sensor faultOn cubed ice makers in the freezer, the board lost the signal from the ice maker sensor.
Er IdFreezer ice maker icing sensor faultThe board is not getting a signal from the icing sensor on the ice maker inside the freezer.
Er IEFreezer cubed ice maker faultThe cubed ice maker in the freezer failed to cycle, has no power, or is jammed with ice.
Er IUFreezer ice maker faultThe freezer ice maker is not working, has no supply voltage, or is frozen up. Some craft ice models also use this code.
Er ItIn door ice maker faultThe ice maker in the fridge door is defective, has no power, or is jammed with ice.
Er ICMini cube ice maker motor faultThe mini cubed ice maker motor is loose, failed, or not getting its 12 volts DC.
Er IOMini cube ice maker sensor faultThe board lost the signal from the temperature sensor on the mini cubed ice maker.
Er ttWater tank switch faultThe switch that detects the water tank is reporting an error.
Er PSProximity sensor faultThe sensor that wakes the display when someone walks up is loose or failed.
Er UCUV dispenser light faultThe UV module that sanitizes the dispenser nozzle has failed. On models that have it, the light runs for 10 minutes every hour on its own.
Er OdWi-Fi module faultThe Wi-Fi module failed, or the board feeding it failed, or a connector came loose.
Er KnRotary knob faultThe control knob is loose, failed, or has no voltage.
Er AdAuto door motor faultThe auto door motor did not reach its open or home position within 5 seconds.
Er ASAuto door reed switch faultThe auto door reed switch reads open when it should be closed.
Er dLLeft auto drawer motor faultThe left auto drawer motor did not reach its open or home position within 5 seconds.
Er drRight auto drawer motor faultThe right auto drawer motor did not reach its open or home position within 5 seconds.
Er LASLeft auto drawer reed switch faultThe left auto drawer reed switch reads closed when it should be open.
Er rASRight auto drawer reed switch faultThe right auto drawer reed switch reads closed when it should be open.
Er CHSealed system high side problemThe control suspects a problem on the high pressure side of the cooling system: a leak, a restriction, a weak compressor or a bad valve. A failed defrost sensor can also trigger it.
Er CLSealed system low side problemThe control suspects a leak on the low pressure side, usually the evaporator. A door left open for a long time or a weak compressor can also set it.
Cycle ErrorTest mode cooldown failedThis only appears during a technician's quick cooling test, when the defrost sensor does not drop below about 38 degrees F within 10 minutes.
OF FDemo mode is on, not a faultThe fridge is in store display mode. The lights and display work but cooling is off in both sections.
t ocInstaView display mode, not a faultA store demo where the InstaView door light turns on for 10 seconds and then off for almost 3 minutes, over and over.
SbSabbath mode, not a faultSabbath mode is turned on, so the display and some features are quiet.
SF / SrTemperature offset mode, not a faultThe fridge is in a calibration mode that lets a technician shift the fridge temperature offset.
SStIce maker fill time setting, not a faultThe calibration menu for the in door ice maker's water fill time is open.
bU / FE / FU / rUNo stored errors, ignoreThese factory codes can appear when the stored error history is recalled. They mean nothing is stored.
1 blinkBoard voltage sensing faultThe compressor drive section of the main board read an abnormal voltage. The board retries after about 30 seconds. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
2 blinksOver voltage or piston over strokeOn standard inverter compressors the board saw its DC bus go above 450 volts. On linear compressors 2 blinks means the piston traveled too far. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
3 blinksCompressor circuit openThe board sees an open circuit to the compressor and shuts it off, then retries. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
4 blinksOver voltage (linear only)Linear compressor models only. The board saw its DC bus go above 450 volts. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
5 blinksCompressor piston lockedThe board cannot detect the piston moving. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
6 blinksCompressor over currentThe board saw too much current on the compressor circuit. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
7 blinksInverter power module shortThe board detected a short in its own compressor drive module. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
8 blinks12 volt DC circuit faultThe board saw a communication fault caused by a shorted 12 volt DC part. The compressor keeps running. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
9 blinksCompressor overloadThe board saw an overload and shuts the compressor off for about 6 minutes. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
10 blinksMachine compartment too hot (linear only)Linear compressor models only. The compressor area went above about 109 degrees F. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
Solid LEDMain board failureThe LED on the main board stays on without blinking. The compressor is off. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.
Fast flashing LED12 volt DC shortThe LED flashes nonstop and the board cuts power to the whole fridge. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off.

Code Keeps Coming Back?

Tell us the code and model, we usually know the fix before we arrive. Same-day across Orange County.

Call (949) 876-7373 Text Us
⚡ $25 OFF For new & referred customers