Most LG refrigerators show an error as Er on one side of the display and a short code on the other, like Er IF or Er FF. Some of these are simple fixes you can try in a few minutes, others mean a fan, sensor or board needs a technician. Here is what each code means and what we check as a factory authorized LG repair team.












| Code | Name | What the refrigerator detected |
|---|---|---|
Er IF | Ice compartment fan not responding | The main board stopped getting a speed signal back from the small fan that pushes freezer air into the ice compartment. Most of the time the fan blade is frozen in place by ice. |
Er FF | Freezer fan not responding | The main board lost the feedback signal from the freezer evaporator fan. Ice built up around the blade is the usual reason, which often means the defrost system is the real problem. |
Er CF | Condenser fan not responding | The fan in the machine compartment at the back bottom of the fridge stopped reporting that it is spinning. That fan cools the compressor and condenser. |
Er dH | Defrost heater circuit fault | The defrost sensor did not warm up to about 40 degrees within 80 minutes of a defrost cycle starting, or the heater circuit is open or shorted. Some models show rdH for the fridge section or fdH for the freezer. |
Er dS | Defrost sensor fault | The main board is not getting a usable reading from the defrost sensor clipped to the evaporator. |
Er rS | Fridge temperature sensor fault | The main board reads the fresh food sensor as open or shorted. The control only sets this code when it sees 0 or 5 volts DC on that line. |
Er rS2 | Second fridge sensor fault | Some models use a second fresh food sensor. The board sees that one as open or shorted. |
Er FS | Freezer temperature sensor fault | The main board reads the freezer sensor as open or shorted, which leaves the control guessing at freezer temperature. |
Er rF | Fridge section fan not responding | The main board lost the feedback signal from the fan that moves air into the fresh food section. |
Er CO | Main board and display not talking | The main board and the display board in the door stopped communicating with each other. |
Er CO2 | Display and dispenser board not talking | The display board and the dispenser board stopped communicating. |
Er C1 | Display and dispenser power board not talking | Either the display board or the dispenser power board stopped sending or receiving data. |
Er Sd | Dispenser sub board not talking | The dispenser sub board lost communication. Depending on the model it talks either to the main board or to the display board. |
Er SC | Door color lighting board not talking | On InstaView models with adjustable color lighting, the small lighting board under the hinge cover lost contact with the display board. |
Er gF | Water flow meter error | The board did not see water flow when it opened the water valve. It can be a failed flow meter or simply no water reaching the fridge. |
Er SS | Pantry drawer sensor fault | The main board is not getting a usable signal from the sensor in the temperature controlled pantry drawer. |
Er CS | Convertible drawer sensor fault | The sensor in the convertible drawer, which gets cold air from the freezer, reads as shorted or disconnected. |
Er HS | Humidity sensor fault | The humidity sensor reads as shorted or disconnected. Some displays show it as H5 or H05. |
Er rt | Room temperature sensor fault | The sensor that reads kitchen air temperature is shorted or disconnected. The fridge uses that reading to adjust cooling. |
Er IS | In door ice maker sensor fault | The main board lost the signal from the icing sensor on the in door ice maker. Some freezer only ice maker models use this same code for their single ice maker sensor. |
Er IH | Freezer ice maker sensor fault | On cubed ice makers in the freezer, the board lost the signal from the ice maker sensor. |
Er Id | Freezer ice maker icing sensor fault | The board is not getting a signal from the icing sensor on the ice maker inside the freezer. |
Er IE | Freezer cubed ice maker fault | The cubed ice maker in the freezer failed to cycle, has no power, or is jammed with ice. |
Er IU | Freezer ice maker fault | The freezer ice maker is not working, has no supply voltage, or is frozen up. Some craft ice models also use this code. |
Er It | In door ice maker fault | The ice maker in the fridge door is defective, has no power, or is jammed with ice. |
Er IC | Mini cube ice maker motor fault | The mini cubed ice maker motor is loose, failed, or not getting its 12 volts DC. |
Er IO | Mini cube ice maker sensor fault | The board lost the signal from the temperature sensor on the mini cubed ice maker. |
Er tt | Water tank switch fault | The switch that detects the water tank is reporting an error. |
Er PS | Proximity sensor fault | The sensor that wakes the display when someone walks up is loose or failed. |
Er UC | UV dispenser light fault | The UV module that sanitizes the dispenser nozzle has failed. On models that have it, the light runs for 10 minutes every hour on its own. |
Er Od | Wi-Fi module fault | The Wi-Fi module failed, or the board feeding it failed, or a connector came loose. |
Er Kn | Rotary knob fault | The control knob is loose, failed, or has no voltage. |
Er Ad | Auto door motor fault | The auto door motor did not reach its open or home position within 5 seconds. |
Er AS | Auto door reed switch fault | The auto door reed switch reads open when it should be closed. |
Er dL | Left auto drawer motor fault | The left auto drawer motor did not reach its open or home position within 5 seconds. |
Er dr | Right auto drawer motor fault | The right auto drawer motor did not reach its open or home position within 5 seconds. |
Er LAS | Left auto drawer reed switch fault | The left auto drawer reed switch reads closed when it should be open. |
Er rAS | Right auto drawer reed switch fault | The right auto drawer reed switch reads closed when it should be open. |
Er CH | Sealed system high side problem | The control suspects a problem on the high pressure side of the cooling system: a leak, a restriction, a weak compressor or a bad valve. A failed defrost sensor can also trigger it. |
Er CL | Sealed system low side problem | The control suspects a leak on the low pressure side, usually the evaporator. A door left open for a long time or a weak compressor can also set it. |
Cycle Error | Test mode cooldown failed | This only appears during a technician's quick cooling test, when the defrost sensor does not drop below about 38 degrees F within 10 minutes. |
OF F | Demo mode is on, not a fault | The fridge is in store display mode. The lights and display work but cooling is off in both sections. |
t oc | InstaView display mode, not a fault | A store demo where the InstaView door light turns on for 10 seconds and then off for almost 3 minutes, over and over. |
Sb | Sabbath mode, not a fault | Sabbath mode is turned on, so the display and some features are quiet. |
SF / Sr | Temperature offset mode, not a fault | The fridge is in a calibration mode that lets a technician shift the fridge temperature offset. |
SSt | Ice maker fill time setting, not a fault | The calibration menu for the in door ice maker's water fill time is open. |
bU / FE / FU / rU | No stored errors, ignore | These factory codes can appear when the stored error history is recalled. They mean nothing is stored. |
1 blink | Board voltage sensing fault | The compressor drive section of the main board read an abnormal voltage. The board retries after about 30 seconds. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
2 blinks | Over voltage or piston over stroke | On standard inverter compressors the board saw its DC bus go above 450 volts. On linear compressors 2 blinks means the piston traveled too far. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
3 blinks | Compressor circuit open | The board sees an open circuit to the compressor and shuts it off, then retries. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
4 blinks | Over voltage (linear only) | Linear compressor models only. The board saw its DC bus go above 450 volts. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
5 blinks | Compressor piston locked | The board cannot detect the piston moving. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
6 blinks | Compressor over current | The board saw too much current on the compressor circuit. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
7 blinks | Inverter power module short | The board detected a short in its own compressor drive module. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
8 blinks | 12 volt DC circuit fault | The board saw a communication fault caused by a shorted 12 volt DC part. The compressor keeps running. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
9 blinks | Compressor overload | The board saw an overload and shuts the compressor off for about 6 minutes. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
10 blinks | Machine compartment too hot (linear only) | Linear compressor models only. The compressor area went above about 109 degrees F. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
Solid LED | Main board failure | The LED on the main board stays on without blinking. The compressor is off. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
Fast flashing LED | 12 volt DC short | The LED flashes nonstop and the board cuts power to the whole fridge. The LED sits on the main board at the back of the fridge, so you will only see it if a technician has the rear cover off. |
Tell us the code and model, we usually know the fix before we arrive. Same-day across Orange County.