The board saw too much water come in, so it runs the drain pump to get rid of it.


We check house pressure with a gauge. Over 120 psi needs a plumber's pressure regulator. We measure the inlet valve coil (about 1.1 kilohms on older 120 volt valves, about 25 ohms on newer 8 volt DC valves) and check whether the board powers the valve when it should not. We also test the flow meter: about 9 kilohms orange to blue, 20 kilohms orange to purple, and 5 volts DC on the signal line.
The board saw too much water come in, so it runs the drain pump to get rid of it.
Turn off the water supply valve if water keeps coming in with the machine off. Check that your home water pressure is normal. Very low (under 20 psi) or very high (over 120 psi) pressure can make the valve leak by.
We check house pressure with a gauge. Over 120 psi needs a plumber's pressure regulator. We measure the inlet valve coil (about 1.1 kilohms on older 120 volt valves, about 25 ohms on newer 8 volt DC valves) and check whether the board powers the valve when it should not. We also test the flow meter: about 9 kilohms orange to blue, 20 kilohms orange to purple, and 5 volts DC on the signal line.
Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.