The main board did not see the tub empty in time.


We check the sump and check valve for debris, then the drain pump. A 120 volt AC pump should read about 20 to 40 ohms. A 3 wire brushless pump reads about 3 to 6 ohms between any two wires and runs near 11 to 12 volts AC (read with a meter that handles inverter pulses) at about 320 RPM in test mode. No output from the board means a board, voltage at the pump with no movement means a new pump.
The main board did not see the tub empty in time.
Remove and rinse the filter in the bottom of the tub. Check the drain hose under the sink for kinks. If the hose goes to a disposal, run the disposal. On a new disposal, make sure the knockout plug was removed. If you have an air gap on the sink, pop the cap and clear debris.
We check the sump and check valve for debris, then the drain pump. A 120 volt AC pump should read about 20 to 40 ohms. A 3 wire brushless pump reads about 3 to 6 ohms between any two wires and runs near 11 to 12 volts AC (read with a meter that handles inverter pulses) at about 320 RPM in test mode. No output from the board means a board, voltage at the pump with no movement means a new pump.
Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.