The motor that switches water between spray arms (the vario motor) is not being detected as turning.


In test mode we check for 120 volts AC to the motor and about 2.7 to 4.0 kilohms on its windings. We also check the position micro switch: 5 volts DC across it when open, 0 volts when closed. Then we replace the motor, switch or board.
The motor that switches water between spray arms (the vario motor) is not being detected as turning.
Make sure nothing blocks the spray arms from turning. Turn power off at the breaker for 5 minutes, then restart.
In test mode we check for 120 volts AC to the motor and about 2.7 to 4.0 kilohms on its windings. We also check the position micro switch: 5 volts DC across it when open, 0 volts when closed. Then we replace the motor, switch or board.
Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.