The defrost sensor did not warm up to about 40 degrees within 80 minutes of a defrost cycle starting, or the heater circuit is open or shorted. Some models show rdH for the fridge section or fdH for the freezer.


We measure the heater with power off. A sheath heater should read close to 44 ohms and an L cord style heater close to 156 ohms. An open reading means a new heater. On many models the defrost sensor comes attached to the replacement heater, so we test the sensor and the wiring at the main board in the same visit.
The defrost sensor did not warm up to about 40 degrees within 80 minutes of a defrost cycle starting, or the heater circuit is open or shorted. Some models show rdH for the fridge section or fdH for the freezer.
Check for frost on the freezer back wall or ice in the drain area. That confirms defrost is failing. Keep doors closed and check that gaskets seal so less moisture gets inside. Unplug the refrigerator or switch off its breaker for 5 minutes, then power it back up and see if the code returns.
We measure the heater with power off. A sheath heater should read close to 44 ohms and an L cord style heater close to 156 ohms. An open reading means a new heater. On many models the defrost sensor comes attached to the replacement heater, so we test the sensor and the wiring at the main board in the same visit.
Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.