The board did not see enough water come in, based on pulses from the flow meter.


We check the inlet screen for debris or scale, then the flow meter wheel and its 5 volt pulse signal to the board. If no water comes in at all, we test the inlet valve: about 900 to 1,300 ohms on 120 volt valves or 20 to 30 ohms on 8 to 12 volt DC valves, plus voltage from the board.
The board did not see enough water come in, based on pulses from the flow meter.
Make sure the hot water valve under the sink is fully open. Check the supply line for kinks behind the dishwasher. Check that other faucets have normal pressure. The dishwasher needs at least 20 psi.
We check the inlet screen for debris or scale, then the flow meter wheel and its 5 volt pulse signal to the board. If no water comes in at all, we test the inlet valve: about 900 to 1,300 ohms on 120 volt valves or 20 to 30 ohms on 8 to 12 volt DC valves, plus voltage from the board.
Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.