The board reads the water temperature sensor as open or shorted. Very hot incoming water, around 194 degrees F, can also set it.


We measure across the thermistor at the board with the unit on. 0 volts DC means shorted, 5 volts DC means open or unplugged. At room temperature the sensor should read about 10 to 14 kilohms. Then we replace the sensor or repair the wiring.
The board reads the water temperature sensor as open or shorted. Very hot incoming water, around 194 degrees F, can also set it.
Check that your water heater is not set extremely hot. Turn power off at the breaker for 5 minutes, then restart.
We measure across the thermistor at the board with the unit on. 0 volts DC means shorted, 5 volts DC means open or unplugged. At room temperature the sensor should read about 10 to 14 kilohms. Then we replace the sensor or repair the wiring.
Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.