The control watched the water level during drain and it did not drop fast enough. Something is slowing the water on its way out, or the pump is not moving it.


Our technician starts at the pump housing and the tub to pump bellows, where socks and coins like to hide, then checks the pressure sensor tube for a blockage. Newer DC drain pumps should read roughly 1.5 to 4 ohms per winding, older 120 volt pumps about 10 to 20 ohms. We run the pump from the test program and confirm the board actually sends it power before deciding between a pump, a harness or a control board.
The control watched the water level during drain and it did not drop fast enough. Something is slowing the water on its way out, or the pump is not moving it.
Turn the washer off, put a towel and a shallow pan under the small door at the bottom front, and clean out the drain pump filter. Pull the washer out and check the drain hose for kinks or a crushed spot behind it. Make sure the hose goes only about 4 inches into the standpipe and is not taped airtight. Check that the hose outlet sits no higher than 96 inches above the floor the washer stands on.
Our technician starts at the pump housing and the tub to pump bellows, where socks and coins like to hide, then checks the pressure sensor tube for a blockage. Newer DC drain pumps should read roughly 1.5 to 4 ohms per winding, older 120 volt pumps about 10 to 20 ohms. We run the pump from the test program and confirm the board actually sends it power before deciding between a pump, a harness or a control board.
Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.