The board reads the water thermistor as open or shorted, so it cannot control water heating.


We measure the thermistor from the main board and again at the sensor. Above about 4.5 volts DC across it the board sees an open, under about 0.5 volts it sees a short. On many models the thermistor is part of the heater, so if the heater is replaced the seal has to be seated evenly or it will leak later.
The board reads the water thermistor as open or shorted, so it cannot control water heating.
Restart on a cold cycle to finish the load. Unplug the machine for 10 minutes, plug it back in and run a short cycle to see if the code returns.
We measure the thermistor from the main board and again at the sensor. Above about 4.5 volts DC across it the board sees an open, under about 0.5 volts it sees a short. On many models the thermistor is part of the heater, so if the heater is replaced the seal has to be seated evenly or it will leak later.
Factory authorized LG repair, parts on the van, 90-day warranty. Same-day across Orange County.